Generator maintenance software for standby power, weekly checks to load bank tests

Keep one record per generator set, with weekly checks, monthly load runs and long tests on schedule, and services triggered by running hours or dates.

Book a demo
Updated 19 Oct 2026
FieldEx scheduling board on desktop with a technician's inspection checklist open on the mobile app, as used by generator service teams

FieldEx is a field service and asset management (FSM+CMMS) application for generator service companies and standby power owners. Every diesel generator set, automatic transfer switch, battery bank and uninterruptible power supply (UPS) has its own record. FieldEx schedules weekly inspections and monthly load runs, and triggers services on running hours or the calendar. It records load and battery readings and keeps every test on file.

What FieldEx does for generator and standby power teams

A standby generator earns its keep on the one day the grid fails. The only way to know it will start is a steady record of weekly checks, monthly runs and on-time services. FieldEx keeps that record on each set, whether you look after one hospital's plant or several hundred sets across client sites. Book a demo to see it with your own fleet, or read our guide to the Best Field Service Management Software.

Every set, switch and battery on record

  • A site record for each location, from a hospital plant room to a telecom shelter. Each holds its address, map pin, contacts and service zone.
  • An asset record in Asset Management for each generator set, automatic transfer switch, control panel and battery bank.
  • Chargers, day tanks and UPS units get records too. Each record holds ratings, serial numbers, and engine and alternator details. Technicians take photos on the job from the mobile app.
  • Parent and component levels, so the engine, alternator, transfer switch and batteries each keep their own history under the set.
  • QR labels on each set and a change history showing who edited what and when.

Services by running hours or the calendar

  • Running-hour meters on each set, with a history of every reading entered from the asset or the job.
  • Maintenance plans that trigger on hours, on the calendar or on whichever comes first, such as 250 hours or 6 months, in Preventive Maintenance.
  • Different checklists and technicians for the weekly inspection, the monthly run and the annual service in one cycle.
  • Missed services rescheduled after a set overdue period, and new sets joining the right plan when they match its criteria.

Load runs, load bank tests and certificates

  • Recurring inspections for weekly, monthly, quarterly and annual checks, each linked to its checklist.
  • Certifications on set frequencies with the certifying body recorded and the test report attached. The 36-month test runs on a maintenance plan with a 36-month interval.
  • Each load bank test and certificate shows as due, overdue or completed, with reminders by email, in-app notification or both, through Compliance Documentation.
  • A dashboard of overdue load runs and load bank tests, those due in the next 7 days and those completed in the last 7 days. Filter it by asset type or service zone.

Readings captured on site

  • Number fields on the job for load in kW or percent of nameplate, run time, exhaust temperature, battery voltage and specific gravity.
  • The running-hour reading taken during an inspection updating the set's meter at the same time.
  • Photos of the control panel and gauges, watermarked with the time they were taken.

Breakdowns and callouts

  • A QR code on each set or site that opens a fault-report form without logging in, and a branded Customer Portal for service requests.
  • Automatic assignment picks a generator technician by skill, availability, shift and leave, plus service zone and live location. A drag-and-drop scheduler handles exceptions.
  • Service-level agreements with several stages, such as attend and restore power, and at-risk and violation alerts per client or set.
  • A warning when a new job repeats a recent job on the same set, so repeat faults are caught, in Work Order Management.

Generator visits on the phone

  • Each job on the FieldEx Mobile App with the set's history, its checklist, the readings to enter and the parts in the technician's own stock.
  • Scan the set's label to open its record, then capture photos, readings and the client's signature.
  • Jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced later.
  • Spare parts such as belts, starter motors and batteries used on each job recorded from the technician's own stock, with low-stock alerts per stock location.

Your own load banks, meters and vans

  • Load banks, clamp meters, battery testers and fuel sampling kits kept as company assets, with serial numbers and the site or van each one is at.
  • Calibration dates on each instrument as recurring certifications, with reminders and the certificate on its record.
  • Service vans and trailers on maintenance plans by date or odometer reading.

Records, reports and contracts

  • A completion PDF for each visit with the set, fault and resolution, and parts with quantities and prices. It also shows check-in and check-out times, attachments and the client's signature.
  • Service contracts with start and end dates, linked to the sets and plans they cover.
  • Reports on sets, run hours, tests and faults by client or site. Export each genset report as CSV, Excel or PDF, or email it on a schedule.

How often must a standby generator be exercised, and how far apart can the runs be?

At least once a month for at least 30 minutes, and in health care no more than 40 days apart. The monthly 30-minute run is NFPA 110 section 8.4.2. Health care adds a spacing rule. The NFPA 99 committee text says generator sets are tested 12 times a year, with intervals of not less than 20 days nor more than 40 days. These tests include a complete simulated cold start and the transfer of essential loads.

What FieldEx does about it

  • A fixed monthly run: each set's monthly exercise runs on a fixed schedule, anchored to a weekday or date, so runs stay evenly spaced.
  • Gaps you can see: reports list each set's run dates by month, so any gap over 40 days stands out.
  • Run time on the record: the start, finish and run time are captured on each run, with check-in and check-out times on the job.
  • Missed runs moved, not lost: a missed run is flagged overdue and rescheduled after the overdue period you set.

What load should a monthly generator run reach, and what goes wrong at light load?

At least 30% of the standby nameplate kW rating, or the manufacturer's exhaust temperature. NFPA 110, the National Fire Protection Association's standard for emergency and standby power, sets these conditions for the monthly run. The Joint Commission's hospital document list uses the same 30% for diesel sets. Each monthly test runs under load for 30 continuous minutes, plus cool-down.

What FieldEx does about it

  • Load as a number: the technician enters the load in kW or as a percentage of nameplate. The exhaust temperature is also a number field on each run.
  • Below 30% flagged: a checklist answer of "below 30% load" raises a follow-up for a supplemental load test.
  • Nameplate on the asset: the set's standby kW rating is kept on its record, so the technician can check the target on the phone.
  • Wet stacking signs logged: observations such as exhaust slobber are recorded with photos, building a history for the engine.

When does a generator need an annual load bank test, and how long does it run?

When the monthly runs don't reach the load threshold. NFPA 110 covers diesel sets that miss the monthly requirement. They are exercised once a year with supplemental loads. Each test runs at least 50% of nameplate kW for 30 continuous minutes, then at least 75% for one continuous hour. The Joint Commission's document list describes the same annual test as 1½ continuous hours with supplemental loads.

What FieldEx does about it

  • The annual test booked when needed: the annual load bank test can run as its own yearly inspection on sets whose monthly runs fall short.
  • Each load step recorded: the 50% and 75% steps are entered as separate readings with their durations.
  • The load bank on the job: the load bank itself can be one of your assets, booked onto the job and moved between stock locations.
  • The report attached: the load bank printout is attached to the completed test record.

What is the 36-month four-hour test for Level 1 emergency power systems?

A continuous test at least once every 36 months, for the system's assigned class, up to 4 hours. NFPA 110 section 8.4.9, sets this for Level 1 emergency power supply systems. Where the class is longer than 4 hours, the test can stop after 4 continuous hours. The Joint Commission's document list sets the same 4-hour test once every 36 months, at no less than 30% of nameplate.

What FieldEx does about it

  • A 36-month plan: the four-hour test runs on a maintenance plan with a 36-month interval, and its job is created well ahead of the due date.
  • Combined visits planned: where the annual and 36-month tests fall together, both records can be completed on one job.
  • Hours recorded through the test: load and temperature readings can be entered at intervals through the 4 hours.

What should a weekly standby generator inspection cover?

A look at the set, its batteries, charger and controls, without running it. The National Fire Protection Association's 2020 article says Level 1 emergency power systems and their components are inspected weekly, and Level 2 systems monthly. The Joint Commission's document list has the emergency power supply system, with all its components and batteries, inspected weekly.

What FieldEx does about it

  • A short weekly checklist: the weekly inspection opens in seconds from a scan of the set. It has one question per item and a photo where needed.
  • Level 1 weekly, Level 2 monthly: each set's inspection frequency follows its level, set on its asset type.
  • Leaks and alarms raise jobs: a failed answer, such as a coolant leak or a charger fault, creates the repair job straight away.
  • Client staff on the round: where the site's own staff do the weekly walk-round, it can be assigned to their users. Client staff who run their own inspections can have a FieldEx user account.

How should generator starting batteries be checked and maintained?

Inspect them weekly, record specific gravity monthly and load test them quarterly. NFPA 110 section 8.3.6 says storage batteries are inspected weekly. For lead-acid batteries, the electrolyte specific gravity is tested and recorded every month. Defective batteries are replaced immediately once found. The National Fire Protection Association's 2020 article adds a battery load test every quarter.

What FieldEx does about it

  • Batteries as components: each battery bank sits under its set, with its install date and warranty.
  • Specific gravity and voltage readings: monthly specific gravity and quarterly load test results are entered as number fields.
  • Replace on discovery: a failed battery check raises the replacement job, with the battery drawn from the technician's own stock.
  • Warranty kept: each battery's warranty period is on the part record for claims.

How often should an automatic transfer switch be tested?

Monthly. NFPA 110 section 8.4.6, says transfer switches are operated monthly. The switch is electrically moved from the primary position to the alternate position and back. For hospitals, the NFPA 99 committee text says each scheduled load test includes automatic and manual transfer of all essential electrical system loads.

What FieldEx does about it

  • The switch on the same visit: the transfer switch's monthly operation is a task on the monthly run job, so both are done together.
  • Transfer times recorded: transfer and retransfer times are captured as number fields.
  • A failed transfer escalates: a failed operation raises an urgent job and can notify your supervisor and the client at once.

How often should stored diesel fuel be tested?

At least once a year. NFPA 110 section 8.3.7 requires a fuel quality test at least annually. The test uses ASTM standards or the manufacturer's recommendations.

What FieldEx does about it

  • A yearly fuel test per tank: each tank's fuel quality test runs as a recurring certification with the lab report attached.
  • A six-monthly option: clients who want twice-yearly testing can have the frequency set to every 6 months.
  • Follow-up work: after a failed fuel result, the job to polish or replace the fuel is raised on the tank's record.

How many running hours should pass between generator services?

The manufacturer sets the interval, by service hours or the calendar, whichever comes first. For US emergency diesel engines, the Environmental Protection Agency's Subpart ZZZZ, Table 2c sets an oil and filter change every 500 hours or within 1 year plus 30 days. The air cleaner is inspected every 1,000 hours or within 1 year plus 30 days.

What FieldEx does about it

  • Whichever comes first: each service runs on a plan that triggers on running hours or the calendar, whichever is reached first.
  • Intervals per engine type: the default meter-based interval is set on the asset type. Each new set of that type starts with the right one.
  • Hours from every visit: hour-meter readings entered on any job update the set's meter and its next service.

How many hours a year can a US emergency generator run for maintenance and testing?

Up to 100 hours per calendar year. The EPA's rule 40 CFR 63.6640, paragraph (f)(2), covers emergency stationary engines. They may run for maintenance checks and readiness testing for up to 100 hours a year. Run hours outside those uses are limited, so each run needs its reason on record.

What FieldEx does about it

  • Hours by year: reports sum each set's run hours from its meter readings by calendar year.
  • Every run recorded: each monthly run, test and repair run is a job with its run time.
  • Running hours on record: test and run hours are logged as meter readings on every set and available in reports.

What must a generator maintenance record show under NFPA 110?

Every inspection, test, run and repair, with the date, the technician and any fix. NFPA 110 sections 8.5.1 and 8.5.3 set out these records for the emergency power supply system. The permanent record goes to the authority having jurisdiction on request. It includes the date of the maintenance report and the identity of the servicing personnel. It also notes any unsatisfactory condition with the corrective action taken, including parts replaced.

  • the domestic trade ministry, Kementerian Perdagangan Dalam Negeri dan Hal Ehwal Pengguna (KPDNHEP, now KPDN), for diesel
  • JAS and occupational safety and health rules for sound and smoke, where they apply
  • registration with Suruhanjaya Tenaga

For a portable genset, its capacity must be at least 80% of the site's loading.

What FieldEx does about it

  • Every event on the set: inspections, runs, tests, repairs and changes are each a record on the generator. Each one carries the date and the technician.
  • Unsatisfactory conditions and the fix together: a failed item and the job that corrected it are linked, so the record shows both.
  • A log on request: reports by set and period export as PDF or Excel when the authority or the client asks.
  • Remote visits offline: jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced later.

How often should a generator service company's own load banks and meters be calibrated?

At an interval that keeps each reading accurate, with the calibration record on hand. NFPA 70B, the US electrical maintenance standard, requires measuring test equipment to be calibrated. Calibration information must be readily available, and intervals must be appropriate to ensure accuracy. The load test records required by NFPA 110 section 8.5 are only as good as the load bank and meters that produced them.

What FieldEx does about it

  • Load banks as assets: each load bank has its own record, rating and location, and is booked onto the job that uses it.
  • Calibration on a cycle: load bank instrumentation, clamp meters and battery testers carry calibration certifications with reminders.
  • Readings traced to kit: the instrument used can be noted on each test job, beside the load readings.
  • Vans and trailers on plans: service vehicles and load bank trailers follow maintenance plans by date or odometer reading.

How often should a genset service firm's own vans and load banks be checked?

Every 6 months for commercial vans, and at each instrument's calibration interval. PUSPAKOM's inspection guide says the Road Transport Act 1987 calls for a routine inspection of every commercial vehicle every 6 months. That covers the vans and trucks carrying load banks to client sites. For the load bank and meters, NFPA 70B, an international standard, requires measuring test equipment to be calibrated.

What FieldEx does about it

  • Vehicle inspections on time: each van's six-monthly inspection is a recurring certification, and its servicing runs by date or odometer reading.
  • Load banks with their own history: each load bank has a record, its calibration date and the site it was last used at.
  • Meters you can vouch for: battery testers and clamp meters carry calibration certifications with reminders, so load test readings stand up.
Customer story

Sime Industrial sells, services and rents heavy machinery for construction, mining and energy customers across Asia Pacific. It represents more than 30 brands. It moved its field service team off Excel and WhatsApp onto FieldEx. Its story describes job updates, statuses and time logs in one place, with live technician locations beside task progress. Reports on job durations and technician performance take a few clicks. It's a different business, but the same work: engines and machines serviced on hours and schedules at customer sites.

Read the Sime Industrial Story

AlanDick has worked in telecom infrastructure in Brunei since the late 1970s, with operations in Malaysia too. It sends up to 26 people a day to onshore and offshore sites. Its FieldEx story describes automatic task assignment by skill, availability and proximity. Tool inspections and procedure audits are scheduled with reminders, and staff certification renewals are tracked. Clients see live service updates through the portal. Its work is close to a genset contract: remote sites, inspected tools and certified people on every visit.

Read the AlanDick Story

Questions generator service teams ask about FieldEx

What is the best generator maintenance software for a standby power service company?

One that covers the records, test cycles and hour-based services described above. FieldEx also shares one asset record between field service and maintenance, so a callout and the set's PPM history sit together. See our guide to CMMS Software.

Can FieldEx trigger a service on running hours or the calendar, whichever comes first?

Yes, as the running-hours section shows. The interval can also be set per set or across a whole plan.

Can technicians record load percentage and run time on each monthly run?

Yes. Number fields on the job capture load, run time, exhaust temperature and battery readings against the set.

Can FieldEx track the 36-month four-hour test?

Yes, as the 36-month test section shows. Where the annual load bank test falls in the same year, both can be done on one job.

Can we test the transfer switch on the same visit as the generator?

Yes. The transfer switch is its own asset under the set, and its monthly operation is a task on the monthly run job.

Can clients see their generators' service history?

Yes. The branded customer portal shows each client its sets with last-serviced dates, upcoming asset maintenance, job status and downloadable reports.

Can we see which sets haven't been run this month?

Yes. The dashboard shows overdue inspections and those due in the next 7 days, and reports list run dates by set and month.

Can a failed weekly inspection create the repair job?

Yes. A failed answer, such as a charger fault or a leak, creates the repair job and its tasks straight away. It can also book a follow-up check.

Can technicians work at remote sites without a signal?

Yes. Jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced later.

How long does it take to set up FieldEx for a generator fleet?

There's no setup fee. Once we know your requirements and your data is ready, FieldEx can be implemented in as little as a week with standard features for small businesses. Larger setups and custom work take longer. Sites and generator sets can be uploaded. FieldEx helps with setup, and training is included. See Setup and Training.

Know every standby set will start, with the record to prove it