Sewer maintenance software for collection systems, lift stations and their crews

Cleaning cycles for every sewer segment, weekly lift station visits, overflow response and grease trap and septic programmes, on one located record per asset.

Book a demo
Updated 15 Oct 2026
FieldEx scheduling board on desktop with a technician's inspection checklist open on the mobile app, as used by sewer maintenance crews

Collection system teams use FieldEx as sewer maintenance software beyond the treatment plant: one system for field service management and maintenance management (CMMS). It keeps every sewer segment, manhole and lift station on its own located record, runs cleaning and inspection cycles, sends crews to blockages and overflows, and manages grease trap and septic programmes.

What FieldEx does for collection system and wastewater field teams

Most sewer problems start in the network, not the plant: grease, roots, failed pumps and blocked laterals. FieldEx plans the work that prevents them and records the work that fixes them, for your own crews and your contractors. Book a demo with a sample of your sewer and manhole register.

The collection system, asset by asset

  • Sewer segments, manholes, lift stations, force mains, odour control units and septic tanks each on their own record, in asset management.
  • Each record holds its asset number, size, material, install date, photos and latitude and longitude.
  • Lift stations as parent assets, with pumps, floats, control panels and standby generators as components.
  • Your own identifiers, such as manhole number or basin code, in renamed identifier fields.

Cleaning and inspection cycles

  • Cleaning, CCTV inspection and manhole inspection plans that raise jobs automatically on their cycles, in preventive maintenance.
  • Shorter cycles for known grease and root hot spots, longer ones for trouble-free lines.
  • Pumps serviced on running hours, on the calendar or on whichever comes first.
  • Plans applied to a whole basin, picking up new segments as they're added.

Lift station visits

  • Weekly lift station visits on each station's site plan, raised automatically for whoever covers it.
  • Visit checklists for pumps, floats, alarms, wet wells and standby power.
  • Failed checklist answers that raise the corrective job before the operator leaves.

Blockages, overflows and customer reports

  • Customer reports of backups, odours or overflows arriving as jobs from a QR form or the portal.
  • Service-level agreement (SLA) clocks with several stages, such as respond, contain and clean up, in scheduling and dispatch.
  • Crews picked by skill, who is free, shift, leave, zone and live location.
  • Follow-up jobs for cleaning, CCTV and root cause raised by the response checklist.

Grease traps and septic programmes

  • Food service establishments' grease traps and interceptors as assets at each site, with pumping and inspection cycles.
  • Septic pumping programmes raised in bulk from an uploaded list of premises.
  • Sludge, grease and volumes removed entered on custom job forms.
  • The app in English, Bahasa Malaysia or Chinese, chosen by each crew member.

Sewer crews, haulers and certificates

  • Contractors in their own accounts, limited to the jobs that involve them.
  • Confined-space entry, gas testing and other certificates held as skills on each crew member, each with an expiry date.
  • Jobs matched only to crews who hold the right skill.

Crews in the field

  • Each crew's route for the day, the history of every manhole or station and its position on a map, on the FieldEx mobile app.
  • Jobs and tasks downloaded and worked offline, with check-in, check-out and travel synced later.
  • Watermarked photos and video with annotation, and the supervisor's signature.

Records the regulator can check

  • A completion PDF for every job, showing the asset, what was done, parts, arrival and departure times, photos and sign-off.
  • Pump reliability as MTBF, MTTR and downtime, and repeat blockages flagged on the same segment.
  • Jobs and inspections reported and exported by basin, asset type or contractor, in reporting and analytics.

How often should sewer lines and manholes be cleaned and inspected?

There is no single national interval. The US Environmental Protection Agency's (EPA) guide to Capacity, Management, Operation and Maintenance (CMOM) programmes says cleaning frequency should follow the problem. A collection system in a restaurant district may need cleaning every six months to prevent grease blockages, while other areas need much less.

State rules set minimums. Kentucky's 807 KAR 5:071, for example, asks sewer utilities to inspect sewers and manholes at intervals of no more than one year, and their mechanical equipment daily.

  1. List your segments and manholes as assets, with location and condition.
  2. Mark hot spots for grease and roots, and give them their own short cycle.
  3. FieldEx raises cleaning and inspection jobs on each cycle, basin by basin.
  4. Each finding raises the repair or follow-up job before the crew leaves.
Septic tank locationScheduled desludging
Within a local authority (PBT) areaEvery 24 months
Outside a local authority areaEvery 36 months

Sources: IWK; Water Services Industry (Desludging Services) Regulations 2021.

What FieldEx does about it

  • Cycles that match the risk: hot-spot segments can run a six-month cleaning plan while others run yearly or longer.
  • Yearly inspections where required: each manhole and segment can carry its own annual inspection, with due dates and reminders.
  • Basin by basin: plans applied to a basin raise jobs together, so crews work one area at a time.
  • Condition on every visit: the inspection checklist records what the crew found, and photos are attached to the job.

What causes sanitary sewer overflows?

EPA's frequently asked questions on sanitary sewer overflows (SSOs) list the causes. They include fats, oils and grease (FOG) and wipes sent to the sewer, tree roots, stormwater and groundwater leaking in, and improper connections. Poor maintenance and cleaning, inadequate pump maintenance, lack of backup power, undersized sewers and equipment failures add to the list.

EPA's pretreatment fact sheet on controlling FOG cites its report to Congress: grease from restaurants, homes and industry is the most common cause of reported blockages, at 47%.

Cause (EPA)Field work that reduces it
Fats, oils and greaseHot-spot cleaning; grease trap programmes
Tree rootsRoot cutting on a set cycle
Inflow and infiltrationCCTV, manhole and lateral inspection
Pump failures and power lossLift station visits; generator testing

Source: US EPA, SSO frequent questions and FOG fact sheet.

What FieldEx does about it

  • Blockages by cause: each blockage job records its cause, so reports show whether grease, roots or debris drive your overflows.
  • Repeat blockages flagged: the same segment needing the same job again within your set number of days is flagged.
  • Generators tested on cycle: standby generators at lift stations carry their own test and service plans.
  • Grease sources easier to find: blockage locations and the grease trap records of nearby food outlets sit in the same system.

How often should a lift station be inspected?

The New England Interstate Water Pollution Control Commission's (NEIWPCC) operation and maintenance guide lists weekly lift station inspection items and a daily log. The Kansas Department of Health and Environment (KDHE) also expects contract operators to visit lift stations weekly.

EPA's lift station webinar adds cleaning cycles. Wet wells should be pumped out and cleaned at least twice a year to stop solids and grease building up. Floats should be cleaned and inspected four times a year, because grease stops them working properly.

TaskHow often
Lift station visit and logWeekly
Float cleaning and inspection4 times a year
Wet well pump-out and cleaningAt least twice a year

Sources: NEIWPCC; KDHE; US EPA lift station webinar.

  1. The first notice date becomes a scheduled job for that premises.
  2. A missed visit is recorded with the reason and a photo of the closed gate.
  3. FieldEx raises the follow-up visit for the second notice date.
  4. The record shows both attempts if the case is escalated.

What FieldEx does about it

  • A visit every week: each lift station's site plan raises its weekly visit for the operator who covers it.
  • Quarterly and twice-yearly tasks alongside: float cleaning and wet well cleaning run as their own plans on the same station.
  • Pump hours drive services: each pump's running hours are logged as meter readings, so services trigger on hours, date or whichever comes first.
  • Faults found on the visit: a failed alarm or float raises the corrective job straight away.

What is a CMOM programme, and what does it need?

EPA's guide for evaluating CMOM programmes describes a framework for managing, operating and maintaining a collection system so it keeps its capacity. EPA's stormwater best-practice sheet lists its parts. It needs an inventory with physical attributes, maps, condition assessment, planned and scheduled work, and repair or rehabilitation based on condition. It also needs timely, relevant information to set priorities.

Permits often write CMOM into their conditions. An Illinois discharge permit, for example, requires schedules for maintenance and sewer cleaning, checklists, and ways to make sure preventive maintenance is done.

RoleCertificate
Authorised entrant, standby personAESP
Authorised gas tester, entry supervisorAGTES (registered with DOSH)
Permit issuerTrained as AGTES
Permit to workUp to 8 hours, plus up to 4 hours

Sources: DOSH ICOP 2010; DOSH confined space guidance.

What FieldEx does about it

  • The inventory, with locations: every segment, manhole and station is an asset with attributes and latitude and longitude.
  • Condition on record: inspection results and photos build each asset's condition history.
  • Scheduled work you can show: plans, completed jobs and checklists show the regulator that maintenance happens on schedule.
  • Information to set priorities: reports by basin and asset show where blockages and repairs cluster.

How often should a restaurant's grease trap be pumped?

Most US cities use the "25% rule". Nashville's Metro Water Services FOG policy is typical. A grease interceptor must be fully pumped when floating grease and settled solids reach 25% of its liquid depth, and at least once every 90 days unless the department approves otherwise.

Smaller grease traps inside kitchens are cleaned far more often. Nashville sets a minimum of every 30 days, and every two weeks where the contents exceed 25%.

What FieldEx does about it

  • Every trap on its own cycle: each food outlet's trap or interceptor is an asset with its own pumping plan, monthly or quarterly.
  • Depth and volume recorded: custom job forms, set up with you during onboarding, can include number fields for the grease layer and volume removed.
  • Over-25% traps on a shorter cycle: move a trap to a shorter plan when it keeps filling early, and its jobs follow.
  • Haulers in their own accounts: approved grease haulers complete the pumping job and photos in their own logins.

How often should a septic tank be pumped?

EPA's septic system guidance says a household septic tank should be inspected every one to three years and pumped every three to five years. Systems with pumps, float switches or other mechanical parts should be inspected more often, generally once a year.

EPA says to pump the tank when the bottom of the scum layer is within six inches of the outlet, or the top of the sludge layer is within 12 inches. It also gives a simpler test: more than 25% of the liquid depth is sludge and scum. Sludge and scum levels should be recorded to set the next pumping date.

What FieldEx does about it

  • Programmes in one upload: pumping and inspection jobs can be raised in bulk from an uploaded list of premises.
  • Cycles per tank: each tank carries its own plan, every three to five years, or yearly for mechanical systems.
  • Levels recorded on site: custom job forms can include number fields for sludge and scum depths, recorded against the job.
  • Owners kept informed: emails and alerts go to the people you choose, and customers with portal access can reschedule their visit.

What should happen after a sewer overflow?

The Illinois discharge permit's CMOM conditions set a clear sequence. The permit holder must identify and report every overflow, and respond to each one to decide on clean-up and other actions. It then finds the root cause and documents it, and plans remedies to reduce the risk of it happening again.

EPA's lift station webinar adds that an overflow emergency response plan should describe the response procedures.

  1. The report arrives as a job with the location and photos.
  2. The response checklist records containment, clean-up and notification.
  3. The checklist raises the CCTV or cleaning job to find the cause.
  4. The cause and the remedy are recorded on the asset's history.

What FieldEx does about it

  • Response clocks: SLA stages for respond, contain and clean up, with alerts before each target.
  • The response plan as a checklist: each overflow opens the same steps, so nothing is skipped under pressure.
  • Root cause recorded: the follow-up job records the cause found, on the segment or station's record.
  • Patterns over time: reports show where overflows recur and which causes dominate.

What confined space rules apply to manhole and wet well entry?

California's Division of Occupational Safety and Health (Cal/OSHA) confined space guide explains how US permit-required confined space rules work. An entry permit, prepared by the employer, is a checklist of every step needed for safe entry and becomes valid once the entry supervisor signs it. Permits should be kept on file for one year.

The guide says to test the air before entry, from outside the space, and at all depths, because some gases are heavier than others. Oxygen is tested first, then combustible gases, then toxic gases.

What FieldEx does about it

  • Only qualified crews: confined-space entry and gas testing can be skills with expiry dates, and entry jobs go only to people who hold them.
  • The permit steps as a checklist: the entry job opens a checklist covering isolation, ventilation, gas tests and sign-off.
  • Gas readings as numbers: custom job forms can include number fields for oxygen, combustible and toxic gas readings, recorded against the job.
  • Records kept with the job: the completed checklist, readings and supervisor's signature stay on the job and the asset.

What records should a sewer maintenance programme keep?

EPA's CMOM guide puts information management at the heart of the programme. You can't prioritise cleaning or rehabilitation without knowing what was done, where and what was found. The Illinois permit asks for the root cause of each overflow to be documented, and for scheduled inspections, testing and cleaning frequencies to be listed.

In practice, every job needs a location, an asset, a date, a crew, a finding and, where relevant, a photo or CCTV report.

What FieldEx does about it

  • Every job on the asset: cleaning, inspection, repair and overflow jobs sit on the segment, manhole or station's history.
  • Reports and video attached: CCTV reports, photos and video attach to the inspection record.
  • Exports for the regulator: jobs and inspections export by basin, period or contractor.
  • Proof of each visit: check-in and check-out times and the completion report show who was there and when.

Questions sewer and wastewater teams ask about FieldEx

What software do sewer utilities use to manage collection system maintenance?

Most combine a map or asset register with software that plans and records the field work. FieldEx covers the field side: segments, manholes and lift stations with their locations, cleaning and inspection plans, overflow response, and every crew's jobs on the phone. Our guide to CMMS software compares the options.

Can FieldEx run different cleaning cycles for grease hot spots?

Yes. Each segment can sit on its own plan, so hot spots run on short cycles and trouble-free lines on long ones.

Can crews find a buried manhole from its record?

Yes. Every manhole carries its latitude and longitude, photos and past inspections, and the mobile app shows where it is on a map.

Can customers report a backup or overflow from a QR code?

Yes. Scanning the QR code opens a form without any sign-in, and FieldEx turns the report into a job at that site. Portal users can raise requests and track them too.

Can FieldEx run a septic pumping programme for thousands of premises?

Yes. Jobs can be raised in bulk from an uploaded list of premises, each on its own cycle, with the tank's history on its record.

Can we track crews' confined-space certificates?

Yes. Name a skill after the certificate and give it an expiry date. Entry jobs then go only to crews who hold it.

Can contractors and grease haulers use FieldEx?

Yes. Each contractor and hauler works in its own logins, and roles decide what they see: only the jobs they're part of.

Can CCTV reports be attached to an inspection?

Yes. Reports, photos and video attach to the inspection record on the segment or manhole.

Can crews work where there's no signal, such as in a basin with poor coverage?

Yes. Jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced when the phone reconnects.

How quickly can a sewer utility start using FieldEx?

Setup, data upload and training come with the subscription: no setup fee, and as much training as your crews need. Your assets, sites and job history can be uploaded. FieldEx helps with setup, and training is included.

Once we know your requirements and your data is ready, FieldEx can be implemented in as little as a week with standard features for small businesses. Larger setups and custom work take longer. See FieldEx implementation.

Bring a section of your collection system to the demo

Book a demo