Biomedical equipment maintenance software for Malaysian hospitals and BEMS teams

Register every medical device by serial number, run its PPM and safety tests on time, and keep the records Act 737 and hospital clients expect.

Book a demo
Updated 16 Oct 2026
FieldEx scheduling board on desktop with a technician's inspection checklist open on the mobile app, as used by biomedical engineering teams

FieldEx is a field service and asset management (FSM+CMMS) application for hospital biomedical engineering units and medical device service companies in Malaysia. Each device has its own record with model, serial number and ward location. FieldEx raises planned preventive maintenance (PPM) and safety tests on schedule. Breakdowns go to competent technicians, and every service report is filed under the device.

What FieldEx does for biomedical engineering teams

In Malaysia, a medical device in use answers to the Medical Device Act 2012 (Act 737) and the Medical Device Authority (MDA). In Ministry of Health hospitals, its upkeep is often contracted out as Biomedical Engineering Maintenance Services (BEMS). Either way, the biomedical team has to show that each device was installed, tested, maintained and taken out of use properly. FieldEx keeps that trail on the device's own record. Book a demo to see it with your own device list.

A register of every medical device

  • One record per device, from syringe pumps and patient monitors to hemodialysis machines and X-ray units.
  • Brand, model and serial number on each record, with photos and warranty.
  • Purchase details and depreciation on each record.
  • Devices grouped by type, category and subcategory, each under its hospital or clinic site.
  • The statuses your unit uses, such as in use, under repair, condemned or disposed.
  • Main units and their components, such as a dialysis machine and its water treatment plant, each with a separate history, in Asset Management.
  • A printed QR or barcode sticker for every device, plus a log of each edit with the user and the time.
  • QR or barcode labels for every device, and a change history showing who edited each record and when.

PPM raised automatically

  • PPM plans that open the jobs on their own, triggered by date, by meter readings such as hours of use, or by whichever arrives first.
  • Separate checklists and technicians for the quarterly, half-yearly and yearly visits in the same cycle.
  • A fixed calendar or a cycle counted from the last finished PPM, with missed PPM moved forward after an overdue period you set. Fixed calendar dates apply to time-based plans.
  • A single plan for all devices of one model, which picks up newly registered devices that fit its criteria, in Preventive Maintenance.

Testing, calibration and certificate dates

  • Scheduled inspections for each device type, each with its own checklist. They can run daily, weekly or monthly, or quarterly, half-yearly or yearly.
  • Calibration and other certificates as recurring records on a set frequency, with the issuing body noted and reminders.
  • Inspection records show the completion date, who performed the inspection, the result, remarks and linked checklist. Certification records can include the completion date, performer, result, remarks and authority, with the certificate or report attached when marked complete.
  • A dashboard showing what is overdue, what falls due within 7 days and what was finished in the last 7 days.

Breakdown complaints from wards and clinics

  • A QR code per hospital or building that opens a complaint form with no login. The form takes the location, the problem, a contact number and photos or video.
  • A branded customer portal where hospital clients lodge requests, ask for a visit date and see where each job stands, in the Customer Portal.
  • An email or in-app alert when a new complaint repeats a recent job on the same device.
  • Response and repair targets per client, counted in working hours across several stages. FieldEx warns before a target is missed and flags it when it is.

Biomedical technicians at the bedside

  • Jobs given out by matching skill first, in Scheduling and Dispatch. FieldEx then checks shift, leave and availability, plus live location and service zone.
  • A drag-and-drop scheduler for the rest.
  • The FieldEx Mobile App on every technician's phone. Technicians scan the sticker, check the device's past jobs and fill in the checklist. They key in test values and capture watermarked photos and the ward's sign-off.
  • Jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced later.

Spare parts in stores and van stock

  • Parts tracked in each store and in each technician's van stock, moved by transfer with barcode scanning and approval steps where required.
  • Reorder and low-stock alerts per location, plus a record of every movement and every part fitted, in Spare Parts Inventory.
  • Each part fitted shown on the job and the device, with its manufacturer and warranty period.

Your own analyzers, simulators and vans

  • Electrical safety analyzers, patient simulators and workshop tools kept as company assets, each with its serial number and location.
  • Calibration due dates for each instrument, with reminders and the calibration certificate on the record.
  • Service vans on maintenance plans by date or odometer reading, with each van's service history on its own record.

Concession contracts, job sheets and reports

  • Maintenance contracts with start and end dates, tied to the devices and PPM plans they cover.
  • A job sheet PDF for each finished job, in Work Order Management. It shows the device, the fault, the fix, and parts and prices. It also shows time on site, photos and sign-off.
  • A log of each email sent.
  • Reports on device reliability, repair cost and age, in Reporting and Analytics.
  • Reports on PPM done against PPM due by hospital or month, exported or emailed on a timetable.
  • CSV, Excel or PDF exports, or reports emailed on a schedule.

What does Act 737 require of anyone who uses or maintains a medical device on patients?

The device must be safe and used to the manufacturer's instructions. It must also be properly installed, tested, commissioned and maintained. Section 43(1) of the Medical Device Act 2012 (Act 737) sets these duties for a medical device used on a third party. The MDA explains why in its FAQ on registration, licensing and enforcement. The people and companies handling installation, commissioning and service, or maintenance and calibration, need to be managed and regulated. That way, devices stay safe and perform at the point of use.

What FieldEx does about it

  • Install, test and commission as one job: a new device's commissioning job holds the steps in order. The technician who did each task signs it off.
  • The manual behind the checklist: the manufacturer's manual is filed on the device. AI can draft checklist questions from a PDF or PNG of your existing checklist or procedure, and your engineers review them.
  • Every PPM on the device's history: each visit is saved with its date, technician, answers and readings, with photos attached to the job.
  • One answer per device: the device record shows its last test, last PPM and next due date at a glance.

Does a person servicing medical devices in Malaysia need set qualifications?

Yes. Section 43(2) of Act 737 covers anyone installing, testing, commissioning, maintaining or disposing of a medical device. That person must have the qualification and competency prescribed by the Minister. The MDA's FAQ lists the many parties whose work carries risk that needs managing. They range from procurement, delivery and storage to device tracking and installation, and on to service, maintenance and calibration.

What FieldEx does about it

  • Skills that match the device: each job type asks for a skill, such as ventilator or dialysis competency. FieldEx offers the job only to technicians holding that skill. Skills can be named after MDA competency or manufacturer training, and carry an expiry date.
  • Vendors on the same rules: vendor engineers can sit in their own group, tried after your in-house team when nobody internal qualifies.
  • A fallback that flags gaps: when no qualified person is free, the job is held unassigned or a supervisor is alerted.
  • Who did what, recorded: each task and inspection names the person who carried it out.

What must happen when a medical device is no longer safe to use?

It must be taken out of operation, then removed and disposed of safely. Section 43(3) of Act 737 says the device must be taken out of operation when it is no longer safe and effective for use. Section 43(4) says it must then be removed and disposed of in a safe manner.

What FieldEx does about it

  • Pulled from use on the spot: a failed answer on the inspection checklist can change the device's status to out of service. It can also raise the repair job at once.
  • Status everyone can see: the inventory, the dashboard and the customer portal all show the device as unavailable.
  • Condemnation recorded: condemned and disposed devices keep their final status, the disposal job and its attachments, with the full history kept.
  • Rented devices tracked: devices on a rental contract show their contract, and whether each is on rent or returned.

Must a medical device be registered with MDA before it reaches a hospital?

Yes. Section 5(1) of Act 737 says no medical device shall be imported, exported or placed in the market unless it is registered under the Act. MDA's medical device registration page repeats the rule. Breaking it can mean a fine of up to RM200,000, up to 3 years in prison, or both.

What FieldEx does about it

  • The registration number on the device: the MDA registration number can be kept with the device's other identifiers.
  • Checked at acceptance: the commissioning checklist can ask whether the registration has been verified, so the answer is on file.
  • Evidence attached: a copy of the registration evidence can be uploaded to the device record.
  • The schedule starts at once: FieldEx adds a device to any existing plan whose criteria it matches. Its first PM is already on the calendar.

How fast must a device problem be reported to MDA?

Within 48 hours to 30 days, depending on severity. Section 40 of Act 737 sets three deadlines:

  • An incident tied to device failure: within 30 days.
  • An incident that led to death or serious deterioration in health: within 10 days.
  • A serious threat to public health: within 48 hours of discovery.

MDA's mandatory problem reporting page adds that an investigation report is due within 30 days after the initial report.

What FieldEx does about it

  • The incident logged with a time: the fault is recorded as a job on the device. Each incident job holds notes, photos and the exact time it was raised.
  • The right people told at once: a workflow can alert the quality or safety lead by email and in the app. It fires when an incident job is opened.
  • Deadlines as stages: a service-level agreement with stages can count down to the initial report and the investigation report. FieldEx warns before each deadline is missed.
  • Reports attached: the submitted report and the investigation findings are attached to the job.

Who acts on a field corrective action or recall under Act 737?

The manufacturer or its authorized representative starts a field corrective action (FCA), and the hospital using or maintaining the device counts as a user. Under section 41 of Act 737, an FCA can mean returning, modifying, exchanging or destroying the device. It can also mean giving specific advice on its use. Section 42(1) lets an establishment recall any defective device at any time. MDA's guidance document MDA/GD/0013 says the manufacturer or authorized representative must notify the Authority before starting an FCA. Its definition of a user includes the healthcare institution using or maintaining the device.

What FieldEx does about it

  • Affected units found by model: the device register filters by brand, model, type or site to list every unit named in the notice. A recall job can be raised for every affected unit in one upload, and each FCA is tracked through to completion.
  • One job per unit: a job for the modification or exchange is opened on each affected device and assigned like any other job.
  • Progress across sites: reports show which affected units are done and which are still open, by hospital.
  • The notice kept on file: the manufacturer's field safety notice is attached to each job.

How long are medical device distribution records kept?

For 2 years after the device is placed in the market, or for its projected useful life if it has one. Section 37 of Act 737 requires an establishment to keep distribution records and to provide them to the Authority on request. Regulation 3(3) of the Medical Device (Duties and Obligations of Establishments) Regulations 2019, P.U.(A) 318/2019, sets the period. Exported devices count from the date they are shipped. Where the device has a projected useful life, the record is kept for that life instead.

What FieldEx does about it

  • Serial numbers by client: each device is linked to the customer and site that holds it.
  • Contracts that list units: service contracts record each device's code and serial number.
  • Exports on request: you can filter the device list by client, model or period and export it for the Authority.

How often should PPM be carried out on medical equipment?

At the interval the manufacturer sets for each model. Section 43 of Act 737 requires devices to be used in line with the manufacturer's instructions and properly maintained. The World Health Organization (WHO) gives the international view in its Medical equipment maintenance program overview (2011). It says the manufacturer's maintenance manual sets how often inspection and preventive maintenance (IPM) is done.

What FieldEx does about it

  • The manufacturer's interval, per model: a PPM plan for each model carries the interval from its manual.
  • Hours as well as dates: devices with hour meters can trigger PPM on usage, the calendar or whichever comes first. Fixed calendar dates apply to time-based plans.
  • Early jobs when needed: a PPM job can be raised before its due date, for example before a device goes on loan.
  • Last and next on one screen: each plan lists its devices with their last and next PPM dates.

Which standard is used for electrical safety testing during maintenance?

IEC 62353, the international standard for medical electrical equipment in use. IEC 62353:2014 from the International Electrotechnical Commission (IEC) covers testing before first use and during maintenance, inspection and servicing. It also covers testing after any repair and at recurrent test intervals. The UK's Medicines and Healthcare products Regulatory Agency (MHRA) adds a warning in Managing Medical Devices. The tests in BS EN 60601-1 are type tests that may damage the device under test, so not all of them belong in routine maintenance.

What FieldEx does about it

  • A recurring test per device type: the IEC 62353 recurrent test is set as a scheduled inspection with its own interval and checklist.
  • Values, not ticks: number fields on the job hold earth resistance and leakage current readings for the device tested.
  • Retested before release: the post-repair safety test is a required task, so a repair cannot be closed without it.
  • Analyzer output kept: the safety analyzer's printout is uploaded to the finished record.

What complaint records must a medical device establishment keep?

A record of each reported problem or complaint, from assessment to corrective action. Section 39 of Act 737 requires an establishment to set up and follow documented procedures and to keep records of reported problems or complaints. Regulation 4(1) of the 2019 Regulations sets what the record holds. The complaint record covers the assessment of the complaint and the investigation carried out. It also covers the corrective and preventive actions (CAPA) taken and the communication with the complainant.

What FieldEx does about it

  • Each complaint a job: complaints from hospital clients through the portal or QR form arrive as time-stamped jobs.
  • Assessment to CAPA in steps: the job holds ordered tasks for assessment, investigation and corrective action, each with an owner and dates.
  • The client kept informed: clients see the job's status in the portal and receive its job sheet when it closes.
  • A complaint log you can export: reports list complaints by client, device or period.

How often must test equipment for medical device servicing be calibrated?

At the specific intervals your procedures set, with a record of every calibration. MDA's Good Distribution Practice for Medical Devices (GDPMD) says equipment used for testing and maintaining medical devices must be calibrated or verified at specific intervals. The calibration and maintenance of that test equipment must conform to the applicable standards. The establishment must also keep testing and commissioning, installation, calibration and maintenance service records. GDPMD ties maintenance procedures to MS 2058, the Malaysian Standard code of practice for good engineering maintenance of active medical devices.

What FieldEx does about it

  • Analyzers on the register: each safety analyzer, patient simulator and defibrillator analyzer your unit owns has its own record, with serial number and location.
  • Calibration on its own cycle: each instrument's calibration runs as a recurring certification. It shows as due or overdue, sends reminders and keeps the certificate on file.
  • Records the Authority can ask for: calibration and repair history for every instrument can be reported and exported for any period.
  • Vans on their own plans: service vans run on maintenance plans by date or odometer reading, with road tax and insurance renewals as recurring certifications.
Customer story

EC Solutions, a technology services provider for airports in Latin America, used to update equipment records by hand in the office after every part swap. On FieldEx, the technician's form updates the equipment record and its linked components the moment it is sent. Removed units are flagged as not in use. Each swap carries a structured failure reason and the technician's and customer's signatures, which keeps its records clean for audits. It's a different industry, but the same need as a biomedical unit: a traceable record of every part swapped on every unit.

Read The EC Solutions Story

Questions Malaysian biomedical engineers ask about FieldEx

Which biomedical equipment maintenance software suits a Malaysian hospital?

One that keeps the device register, PPM, safety tests, complaints and job sheets on each device's own record, as described above. FieldEx adds field service management on the same records, so concessionaires, vendors and in-house units work from one history. See our CMMS Software Guide.

Can a BEMS concessionaire run several hospitals on one FieldEx account?

Yes. Each hospital is a site under its client, and PPM plans can span many sites. Hierarchy levels and permission profiles keep each hospital team to its own records.

Can the hospital's engineering unit see the concessionaire's work?

Yes. The branded customer portal shows the hospital its devices with last-serviced dates, upcoming asset maintenance, open and completed jobs and downloadable job sheets.

Can FieldEx remind us before a device's calibration falls due?

Yes. Calibration runs as a recurring certification on a set cycle, shown as due or overdue, with email or in-app reminders.

Can technicians key in leakage current readings on the phone?

Yes, as the safety-testing section above describes. Each reading is recorded against the job, so the device's history shows every value since commissioning.

Can ward nurses report a broken device without logging in?

Yes. Scanning the hospital's QR code opens a complaint form with photos or video, and the complaint lands in the backlog as a job.

Can we see which devices break down most often?

Yes. FieldEx reports mean time between failures (MTBF), mean time to repair (MTTR) and downtime for every device as standard. Reports also rank models by repair count, repair cost and age, and a repeat job on the same device is flagged automatically.

Does the FieldEx app work in Bahasa Malaysia?

Yes. The FieldEx web and mobile apps are available in English, Bahasa Malaysia and Chinese, so each technician can work in the language they read best. Jobs and tasks can be downloaded and worked offline, with check-in, check-out and travel synced later.

Can we track spare parts across hospital stores and van stock?

Yes. Each store and each technician's van stock is tracked, with transfers, reorder alerts and a history of every part fitted on each job.

How soon can our biomedical unit start on FieldEx?

There's no setup fee. Once we know your requirements and your data is ready, FieldEx can be implemented in as little as a week with standard features for small businesses. Larger setups and custom work take longer. Devices can be uploaded. FieldEx helps with setup, and training is included. Onboarding is in person in Malaysia as well as online. See Setup and Training.

Keep every medical device's PPM, tests and job sheets in one register

Book a Demo